Introduction:

In this blog post, we will discuss about how to post material documents with own defined MVT types for goods movements initiated from EWM system.

One simple example is – once we confirm put away WT in EWM then system posts 411 material document  in S4 core system for doing a transfer posting from ROD storage location to AFS storage location. Note: You can also work with only AFS storage location, There is no strict need to work with combination of ROD and AFS.

Solution Approach:

First thing that should come to your mind is- why system post transfer posting with MVT type 411?

Table /SCWM/TIMBWA will have answer to your question.

 

Now next question is – let say If I want to post transfer posting material document with 911 MVT type instead of 411 then how to setup this?

Ok- well, just create new MVT type 911 copying original MVT type 411.

Now go to below EWM customizing node to steer system to go to 911 from 411.

You are all done.

Now when you trigger any GM that was supposed to be posted with 411 in S4 core will be posted with MVT 911.

Just look at below example:

SAP standard setup-

Test with our new setup-

Conclusion: 

After following this blog post, you can setup the system to have your own defined MVT type for GM initiated from EWM system.

Thanks for your time to go through this blog post.

Please don’t hesitate to provide your feedback and suggestions to make this blog post even more productive and informative.

Thanks

Regards

ASLAM

5 Comments
You must be Logged on to comment or reply to a post.
Author's profile photo Minh Tran Nguyen Ngoc

Minh Tran Nguyen Ngoc

May 27, 2022 at 7:04 am

Hi Aslam,

Thank for your topic, but if the Logical System is blank like your picture, the system show error like this.

An RFC destination could not be specified for the logical system DS4CLNT100

Message no. B1550

Is there any problems ?

Thanks.

Kent.

Author's profile photo Aslam Ansari

Aslam Ansari

Blog Post Author

May 27, 2022 at 7:11 am

Hello

I am using embedded system , so I don’t need to mention the logical system.

If you have decentralized EWM, then you need to mention logical system of the connected ECC system (Hopefully it should be of ECC, not 100 % sure, you need to test).

Regards

ASLAM

 

Author's profile photo Minh Tran Nguyen Ngoc

Minh Tran Nguyen Ngoc

May 27, 2022 at 7:28 am

Hi Aslam,

Thank for your advise, I have found the missing configuration and update.

Kent.

Author's profile photo Aslam Ansari

Aslam Ansari

Blog Post Author

May 27, 2022 at 9:14 am

Great that you have fixed it.

Author's profile photo Minh Tran Nguyen Ngoc

Minh Tran Nguyen Ngoc

November 21, 2022 at 10:36 am

Hi Aslam,

 

Please help me with this case.

I use /SCWM/POST to transfer batch A to batch B (same material)

But when I create WT, system show error “Enter Plant”

My config link 309 to Z08 (my new mvt)

But in /SCWM/TIMBW no Posting StrRef 309, so i can’t understand how the system can create material document with mvt 309 when i’m not assign this config.

Now i have this issue after assign this mapping to Z08

 

Sara Sampaio

Sara Sampaio

Author Since: March 10, 2022

0 0 votes
Article Rating
Subscribe
Notify of
0 Comments
Inline Feedbacks
View all comments
0
Would love your thoughts, please comment.x
()
x